New

VT593 / Spot Leak Sensor

Description

The sensor detects water by increasing capacitance on two metal poles. The detector is encapsulated in plastic housing. Due to the low applied voltages and the applied leakage detection principle, it does not rust over time.

Can be connected to any analog port (A1...A8) of the Vutlan monitoring unit.

The maximum amount of sensors and maximum length can be extended using the VT408 / Sensor extension unit.

Downloads

Specifications VT593

Type of sensor:
Analog sensor
Detection:
Capacitive
Daisy chain
No
Description
The sensor has two RJ connectors. RJ 6P4C connects to the analog port of Vutlan monitoring system. RJ 4P2C connects the leak detector with two poles.
Dimensions:
60×18×18 mm
Inputs:
2 wire (WDC cable)
Outputs:
RJ11 / RJ12 (6p4c)
Operating temperature:
-10 °C to +80 °C
Operating humidity:
5% to 95% (Non-Condensing)
Power consumption:
60 mW
Mounting:
Mounting bracket included.
Max. distance:
100 m from the monitoring and extension unit
Response time:
15 seconds
Recovery time:
Depends on how fast the sensor dries out
Manufactured in:
Slovak Republic, E.U.
HS Code:
9025 80 400
GTIN:
8588009886228

Specifications VT593

Description:
The detector is used in combination with the "VT593 / Spot leak sensor" for level monitoring of conductive liquids in containers, pits, cellars, etc. The sensor has two stainless steel poles. The detector is encapsulated in plastic housing for conductive liquids. The sensor can be connected to dry contact inputs (e.g. an alarm system). Can be placed near plumbing, trays, raised floors, under equipment, sinks, aquariums, sump pumps, refrigerators, dishwashers, toilets, basements, washing machines, water heaters, and garages.
Dimensions:
30x20x8 mm
Cable length:
1-meter cable
Operating humidity:
20%RH~100%
Working temperature
-10℃~50℃
Outputs
Two wires, RJ 4P2C plug.
Output form
NO normally open
Special features
The measuring electrodes are resistant to chlorine and salt water (stainless steel AISI 316 / V4A)

Sensor features

Logic schemes

Logic schemes are used to specify automatic actions to events that occur in the system.

Dashboard view

The system allows to customize the dashboard individually for each user and displays the most important information on it in a visual form.
Add widgets with multi graphs, gauge meters or knobs.

Thresholds

Each sensor has Low Alarm, Low Warning, Normal, High Warning, and High alarm threshold states for logic control & sending of notification.

Graphs and Logging

Vutlan supports SD card logging up to 500 Gb. You can log a whole systems loaded with sensors for 3 years.

Add more analog sensors using VT408 or VT408DIN

'VT408 Sensor extension unit' and 'VT408DIN Sensor extension unit" increase the number of analog sensors connected to any Vutlan monitoring unit. Each VT408 unit adds 8 analog sensors. Multiple VT408 units can be connected using a daisy CAN chain. Sensors connected to the extension unit appear in the system automatically.

Systems with analog ports:

To read data from the analog sensors, you need Vutlan monitoring and control system. All the following monitoring & control systems have a different amount of analog ports.